MET 6.3
Emission Tester Combi Tester Petrol/Diesel
VP 135213
Description |
- Emission tester stands out due to limited weight and compact design
- Short warm-up time, quick measurement readiness
- One single probe sufficient for diesel and petrol
- Accurate analysis of gas components HC, CO, CO2, O2 with lambda value calculation
- Time-saving and easy testing/diagnosis of opacity/particle concentration using the partial flow method with free acceleration or engine under load
- Intuitive operation, clear structure in emissions testing process as set out in current guidelines 5 enable minimum cycle times
- The MAHA VCI makes EOBD analysis easy
- Innovative condensate separation thanks to active water separator
- Easy to maintain thanks to optimum accessibility
- Future-proof with the latest technology
- All measurement values HC, CO, CO2, O2, K-value, turbidity, particle concentration can be displayed simultaneously
- Option:
○ Expandable for NOx analysis; (nitrogen monoxide (NO) and nitrogen dioxide (NO2) are measured separately)
○ W-LAN interface
Petrol Tester Module Description:
- Partial flow emission tester with display unit (basic device) for analysis of gas components HC, CO, CO2 and O2 with lambda value calculation
- Emission testing of CNG, LPG and petrol engines possible
Diesel Tester Module Description: Official German PTB-approval 18.09
- Instantaneous or continuous measurement
- Options:
○ W-LAN interface
Standard Delivery:
- Basic units: gas analyser and opacimeter/particle measurement device in a high-quality synthetic casing with integrated display unit and keypad
- Steel mesh emission probe, 600 mm, 2000 mm probe tubing
- LAN interface with LAN cable (RJ 45)
- Power supply unit 110V - 230V, 50/60Hz
- Transparent drain hose for condensed water with collecting tank
- Main filter, zero filter and condensate filter
- Electrochemical O2 sensor
- Trigger tongs for MET 6.3 for inductive RPM measurement at ignition cables
- 2 replacement filters, 2 replacement seals
- Measurement software for continuous measurement and control of MET without country-specific test procedure
Technical data |
Measurable gases | HC, CO, CO2, O2 |
Measuring principle Infrared spectrometry | HC, CO, CO2 |
Measuring principle Electrochemical detection | O2 |
Flow | 3.5 l/min |
Accuracy class | O (OIML) |
CO - Measurement range / Measured value resolution (max.) | - 15 % Vol. / 0,01 |
CO2 - Measurement range / Measured value resolution (max.) | - 20 % Vol. / 0,01 |
HC - Measurement range / Measured value resolution (max.) | - 9999 ppm / 0,1 |
O2 - Measurement range / Measured value resolution (max.) | - 25 % Vol. / 0,01 |
Lambda (calculated) | 0,5 - 9,99 / 0,01 |
Warm-up time of the measurement chamber approx. | 150 s |
Measuring range particle concentration | - 1100 mg/m³ |
Resolution of particle concentration | 1 |
Measurement range turbidity | - 100 % |
Measuring range absorption coefficient | - 9.99 m-1 |
Resolution absorption coefficient | 9.99 m-1 |
On-board voltage | 10 V / 30 V |
Power supply | 1/N/PE 110 V/230 V 50 Hz/60 Hz |
Ambient temperature | 0 °C - 45 °C |
Operating height | -10000 mm - 300000 mm |
Dimensions total (L x W x H) | 160 mm x 225 mm x 406 mm |
Weight | 5.0 kg |
Images |
Request for quotation